摘  要:APS 报警系统是AP1000 核电厂控制的重要人机接口,操纵人员通过该报警管理工具可迅速识别机组的状态变化,很大程度上提高电厂运行业绩。但瞬态情况下过多的报警会增加操纵人员的负担且可能使重要信息被淹没。对瞬态情况下报警情况改进不仅可提高运行安全性,也是电站提升运行业绩的重要策略。


关键词:报警;瞬态;报警抑制



中图分类号:TP277        文献标识码:A        文章编号:2096-4706(2018)03-0006-02


Handling Strategy for APS Alarm System of AP1000 Main Control Room Under Transient Condition

XING Zhaohong

(Operation Department of Sanmen Nuclear Power Co.,Ltd.,Taizhou 317112,China)

Abstract:The APS alarm system is an important man-machine interface for the control of AP1000 nuclear power plant. Theoperator can quickly identify the state change of the unit through the alarm management tool. To a great extent,the performance of powerplant is improved. However,excessive alarm under transient condition will increase the burden of operator and may cause importantinformation to be submerged. The improvement of alarm situation in transient situation can not only improve the safety of operation,butalso increase the safety of operation. It is also an important strategy for improving the operation performance of the power station.

Keywords:alarm;transient;alarm suppression 